YOUR HOME / YOUR ENERGY / YOUR CHOICES

See what smarter
energy could change.

Build a picture of your home. Follow the electricity through a winter evening and a summer afternoon. Then compare the options—not just the sales pitch.

Model my home
SOLAR + BATTERY + HEAT PUMPOne home.
Four possibilities.

Half-hourly energy flows.
A full year of seasonal comparisons.

Educational estimates · not a quotation or guaranteed saving

A simulation, not a promise. Seasonal demand and sunshine are modelled. All four options use the same home and import tariff. Equipment settings are generic, not measured Sigenergy performance.

YOUR MODELLED YEAR

13,500 kWh.
Now give it a smarter route.

3,500 kWh base use + 10,000 kWh heat-pump electricity. No gas bill or heating-system replacement saving is included.

Tariff basis: illustrative prices—not a live supplier tariff. Every model day repeats the selected profile.

Annual net electricity bill£1,724Import + standing − export credit
Annual bill reduction£1,989Versus grid only on this same tariff
Demand met by your solar34%Direct + solar-charged battery energy
FOLLOW A DAY

Same home. Different seasons.

Representative Jan 15 · Solar + battery
Solar generation0.00 kW
Grid connection3.76 kW in0.00 kW exported
3.76 kWHome demand
Battery0.00 kWIdle · 0.0 kWh stored
Base load 0.79 kW Heat pump 2.97 kW electrical

Power averaged over this half-hour. Battery stored energy excludes the reserved capacity.

Day’s demand 64.4 kWhDay’s solar 5.2 kWhImport at 18:00 30.00p/kWh
0.01.83.500:0006:0012:0018:0023:30kWh per half-hour
Home demandSolar generationGrid import
Battery charge & tariff profile
0.07.214.400:0006:0012:0018:0023:30kWh stored
Battery stored energy
0.015.030.000:0006:0012:0018:0023:30p/kWh
Assumed import price
Exact half-hour figures (accessible data table)
Jan 15: energy in kWh per half-hour; stored energy is at interval end.
TimeHomeSolarImportExportBattery → homeStoredp/kWh
00:001.010.003.510.000.002.378.00
00:301.010.003.510.000.004.748.00
01:001.010.003.510.000.007.128.00
01:301.010.003.510.000.009.498.00
02:001.010.003.510.000.0011.868.00
02:301.010.003.510.000.0014.238.00
03:001.010.001.190.000.0014.408.00
03:301.010.001.010.000.0014.408.00
04:001.010.001.010.000.0014.408.00
04:301.010.001.010.000.0014.408.00
05:001.010.001.010.000.0014.408.00
05:301.010.001.010.000.0014.408.00
06:001.770.000.000.001.7712.5330.00
06:301.770.000.000.001.7710.6730.00
07:001.770.000.000.001.778.8030.00
07:301.770.000.000.001.776.9330.00
08:001.770.050.000.001.725.1230.00
08:301.770.150.000.001.623.4130.00
09:001.060.240.000.000.822.5430.00
09:301.060.320.000.000.741.7630.00
10:001.060.400.000.000.671.0630.00
10:301.060.450.000.000.610.4230.00
11:001.060.490.180.000.400.0030.00
11:301.060.510.550.000.000.0030.00
12:001.060.510.550.000.000.0030.00
12:301.060.490.570.000.000.0030.00
13:001.060.450.610.000.000.0030.00
13:301.060.400.670.000.000.0030.00
14:001.060.320.740.000.000.0030.00
14:301.060.240.820.000.000.0030.00
15:001.060.150.910.000.000.0030.00
15:301.060.051.010.000.000.0030.00
16:001.880.001.880.000.000.0030.00
16:301.880.001.880.000.000.0030.00
17:001.880.001.880.000.000.0030.00
17:301.880.001.880.000.000.0030.00
18:001.880.001.880.000.000.0030.00
18:301.880.001.880.000.000.0030.00
19:001.880.001.880.000.000.0030.00
19:301.880.001.880.000.000.0030.00
20:001.880.001.880.000.000.0030.00
20:301.880.001.880.000.000.0030.00
21:001.880.001.880.000.000.0030.00
21:301.880.001.880.000.000.0030.00
22:001.060.001.060.000.000.0030.00
22:301.060.001.060.000.000.0030.00
23:001.060.001.060.000.000.0030.00
23:301.060.001.060.000.000.0030.00
THE SEASONAL PICTURE

Summer surplus.
Winter reality.

Solar is weighted towards summer; heat-pump demand towards winter. A battery moves energy between hours, not from July to January.

Home electricity demandSolar generation
Monthly energy and net bills · Solar + battery
MonthDemand kWhSolar kWhImport kWhExport kWhGrid-only billSelected bill
Jan1,9971621,8820£532£394
Feb1,7682701,5410£472£310
Mar1,5974321,2130£430£212
Apr1,18859469141£325£78
May7977021250£226£26
Jun4887561240£147£15
Jul4977560238£150£16
Aug4976480125£150£16
Sep7884863360£223£42
Oct1,0973248260£303£118
Nov1,2881621,1710£351£215
Dec1,4971081,4360£405£283
COMPARE BEFORE YOU COMMIT

Four options. One fair baseline.

Changing hardware is the only difference below. The home demand, prices and standing charge stay the same. Bill reductions exclude buying and maintaining the equipment.

The battery’s extra contribution: £982 annual bill reduction compared with solar alone. This is already included in the total saving above—not an extra amount to add.

Imported electricity
£1,541
Standing charges
£183
Solar export credit (subtracted)
£0
Net annual electricity bill
£1,724
KEEP THE NUMBERS HONEST

What this model knows.
And what it doesn’t.

Energy is accounted for

Annual conversion loss: 478.2 kWh. Solar curtailed at the export limit: 0.0 kWh. Year-end stored energy: 0.0 kWh, with no cash value added.

Not an off-grid promise

Solar coverage excludes grid-charged battery energy. Reserved capacity is withheld, not free energy. Backup capability, heat-pump starting loads and electrical supply limits need an installation design.

Read the assumptions & dispatch method
  • 365 days, 48 half-hour slots each. Base demand uses your chosen daily pattern; monthly heating weights are normalised from 17/15/13/9/5/2/2/2/5/8/10/12, with modest morning/evening peaks. In heat-input mode, one annual SCOP converts heat to electricity; temperature-dependent efficiency is not modelled.
  • Solar shares are normalised from 3/5/8/11/13/14/14/12/9/6/3/2. Daylight lengths vary by month. These are synthetic teaching profiles, not measured weather, a postcode-specific roof estimate or an MCS yield calculation. Every day within a month has the same demand and solar profile.
  • Each selected tariff profile repeats every day. Published Agile data is a trailing 24-hour sample grouped into UTC slots, not a seasonal or annual price forecast. No daylight-saving shift, weekday variation or future price prediction is included.
  • Solar meets demand first. Surplus can charge storage if later import value exceeds forgone export after losses. Remaining surplus exports up to your limit; the rest is curtailed. The model never exports battery energy.
  • A rolling 24-hour look-ahead uses lower-price slots to charge towards expected higher-price demand, allowing room for forecast solar. This is a simple heuristic, not an optimal controller or a simulation of mySigen software. Real weather forecasts and controls can perform differently.
  • Charging and discharging each apply the square root of round-trip efficiency. Battery power and available capacity are capped; no simultaneous battery charge and discharge. Storage starts empty and carries between days and months. Reserve is removed from available capacity.
  • No inverter standby demand, battery ageing, PV inverter clipping beyond the entered net solar yield, maintenance, financing, grant, gas saving or supplier exit fee is included. Confirm smart-meter and tariff eligibility, export permissions and exact equipment.
  • Rounding is display-only; the downloadable monthly figures retain two decimals. Net bills can be negative if assumed export credits exceed import and standing costs—this is not a supplier-payment guarantee.

Octopus public API documentation · All non-published tariff and energy profiles are editable modelling assumptions.

Sigenergy showroom
TURN AN ILLUSTRATION INTO A DESIGN

Like the direction?
Let’s check your home.

A roof survey, your consumption data and the exact Sigenergy specification turn assumptions into a proposal worth considering.

Discuss my home energy plan