Size 06
5.2 kW
Rated output at A−7/W55 · EN 14511
- At A−7/W35
- 5.46 kW
- Sound power: ErP / maximum
- 48 / 56 dB(A)
- R290 charge
- 1 kg
- SCOP / price
- Not verified / Not quoted
Reference only — cannot apply to design
R290 monoblock range, sizes 06 / 08 / 10 / 12, with distinct V004 protective-heater and V005 comfort-heater versions. These records are not selectable equipment and do not change your current design.
Manufacturer notice — 6260605, p.93
“These specifications are provisional. The specifications at the time of delivery of the series product are definitive.”
Final specifications, design-condition performance data and the exact system arrangement require manufacturer verification before this range can be selected or quoted. Automatic recommendations, pricing, customer proposals and installation drawings are disabled for this range.
5.2 kW
Rated output at A−7/W55 · EN 14511
Reference only — cannot apply to design
7.0 kW
Rated output at A−7/W55 · EN 14511
Reference only — cannot apply to design
8.4 kW
Rated output at A−7/W55 · EN 14511
Reference only — cannot apply to design
9.4 kW
Rated output at A−7/W55 · EN 14511
Reference only — cannot apply to design
Published points are at −7°C outdoor air, not your property’s design temperature. They are not interpolated into performance curves. Sound figures are sound power, not sound pressure at a neighbour’s window. Source: 6260605 pp.93–95.
Maximum flow 75°C; maximum at −10°C outdoor air 70°C. Heating refrigerant-circuit switch-on -20°C / switch-off -25°C. Maximum cooling air inlet 45°C. These are limits, not guaranteed output or efficiency at every condition.
| Size | ηs W35 / W55 | Max current | Dimensions mm | Weight |
|---|---|---|---|---|
| 06 | 202% / 151% | 14 A | 530 × 1140 × 808 | 93 kg |
| 08 | 202% / 153% | 14 A | 530 × 1140 × 808 | 93 kg |
| 10 | 208% / 155% | 16 A | 530 × 1140 × 1008 | 118 kg |
| 12 | 204% / 155% | 20 A | 530 × 1140 × 1008 | 118 kg |
Outdoor-unit supply: 1/N/PE 230 V~/50 Hz. G 1 male thread — heating water flow/return. Maximum secondary-side operating pressure: 3 bar.
V005 heater supply is additional; outdoor-unit current alone is not total installation demand.
6260605 · Vitocal 200-A outdoor unit — installation and service · 104 pages
User-supplied launch edition; provisional
6261130 · IDU controller IW B1-V — installation and service · 88 pages
User-supplied launch edition
6260634 · Vitocal 200-A outdoor unit — connection and wiring diagram · 36 pages
User-supplied launch edition
The manufacturer’s schematic browser lists Vitocal 200-A ie arrangements. These have not been approved or imported into our automatic schematic engine. Regional applicability and exact IDU/variant must be checked.